Rheem Tankless Error Codes: DIY Troubleshooting guide and Repair Tips
Rheem tankless water heaters are renowned for their energy efficiency and continuous hot water supply. However, as with any intricate system, occasional problems may arise that demand your attention.
When an error code appears on your Rheem tankless water heater, it serves as a clear indicator that some action is needed.
These error codes are specifically designed to offer diagnostic information, making it easier for homeowners to identify and resolve issues promptly.
Whether you’re encountering challenges with water flow, gas supply, ignition, temperature fluctuations, or any other tankless problem, this guide will provide you with the necessary knowledge and meanings of the most common Rheem tankless error codes. By following the step-by-step troubleshooting instructions provided here, you can save both time and money by avoiding unnecessary repairs.
It is important to keep in mind that while some issues can be resolved through simple maintenance tasks, others may require the expertise of a professional repair service.
Every Rheem tankless water heater, whether it’s non-condensing or condensing, relies on a computer board to oversee the heating process, make parameter adjustments, and aid in the diagnosis of potential issues.
Thanks to the implementation of an electronic control board and advanced technology, including the availability of an optional remote controller and control panel, the diagnostic process is streamlined and more straightforward for Rheem tankless heaters.
In the event of a problem, the error code is conveniently displayed on the LCD screen of the remote or user interface. By understanding the significance of these error codes, troubleshooting becomes significantly more manageable.
List of Rheem Tankless Error Codes and Repair Tips
We will assume that your Rheem tankless water heater was professionally installed by a licensed plumber/installer. If an error code appears on the screen, there are a few steps you can take before reaching out to service support. Following these steps may help reset the system and potentially resolve the issue:
- Turn the hot water tap OFF.
- Turn OFF the remote control.
- Wait for approximately 5 minutes.
- Turn the unit ON.
- Open the hot water faucet.
If, after performing the reset and the error code remains visible without any changes, please proceed with the following steps:
- Close the hot water tap and turn OFF the remote.
- Consult the error code guideline provided below to identify the problem. If the code differs from those listed here, it is advisable to contact a licensed technician for further assistance.
Error Code 1L
Cause: Limescale deposits in the heat exchanger lead to reduced water flow and a significant increase in temperature.
Solution: To address this issue, it is necessary to descale the water heater. Here is an example of how to descale a Bosch tankless heater.
Error Code 05
Cause: The air supply pipe, exhaust vent, or their connections/terminations may be obstructed or improperly installed. An audible alarm sounds every 60 seconds when a tap is open.
Solution: If you are unable to identify the issue within the venting system or remove any obstruction hindering normal operation, it is recommended to call the service.
Error Code 11
Cause: The gas shutoff valve is not fully open.
Solution: Ensure that the gas shutoff valve is fully open, allowing sufficient gas flow to the main gas burner, and check for any obstructions that may be impeding the gas supply.
Error Code 12
Cause: Insufficient gas supply to the water heater and burner.
Solution: If your tankless water heater operates on natural gas, ensure there are no interruptions in the gas supply from the distributor. If using propane gas, ensure that the propane tank has an adequate amount of gas available.
Error Code 13
If none of the steps mentioned above resolve the issue, it is recommended to contact the service for further assistance.
Error Code 14
Contact a technician immediately if your water heater is experiencing overheating.
Error Code 15
Cause: In many instances, the water heater fails to start due to the hot water tap not being fully open, resulting in low water flow. Another potential issue that can arise from reduced water flow is the heat exchanger reaching excessive temperatures.
Solution: Ensure that the hot water tap is opened to an extent that provides the minimum required water flow.
Troubleshooting Error Code 29
Error code 29 on a Rheem tankless water heater typically indicates a problem with the neutralizer or condensate system. Here are the 5 common causes and solutions for this error:
Cause #1: Clogged Condensate Drain Line
A clogged condensate drain line is the most common cause of error code 29. The blockage prevents proper drainage, causing the neutralizer to fill up with condensate and triggering the error.
Fix: Disconnect and flush the condensate line with a garden hose to clear the blockage. Reinstall it afterward. If the line is glued, install a neutralizer kit.
Cause #2: Incorrect Condensate Line Piping
Incorrect condensate line piping, such as upward slopes, trapped lines, or improper pipe sizes, can prevent the condensate from draining properly, leading to the neutralizer failing.
Fix: Ensure the condensate drain is near the water heater and that the pipe slopes downward for proper flow. If needed, install a condensate pump or contact a technician.
Cause #3: Clogged or Filled Condensate Neutralizer
If the neutralizer is clogged or filled with water, error code 29 will appear. This occurs when the neutralizer becomes obstructed or accumulates too much water, halting the flow of condensate.
Fix: Turn off the power, unscrew the bracket and nuts holding the neutralizer, disconnect the drain tubes and wires, and remove the neutralizer. Flush it with water and shake it to remove buildup. Reinstall the neutralizer following the steps in reverse. For new installations, confirm that the neutralizer’s cap on the bottom has been removed.
Cause #4: Wet Neutralizer Sensor Wires
Wet sensor wires can cause error code 29 by sending incorrect signals to the control board.
Fix: Ensure the two sensor wires on top of the neutralizer are dry. Use a paper towel or clean cloth if necessary to dry them.
Cause #5: Defective Control Board
A defective control board can fail to receive signals from the neutralizer sensor, triggering the error code.
Fix: Before replacing the control board, inspect and clean the condensate drain, as it’s often the cause of the error. If the issue persists, replacing the control board may be necessary.
Error Code 31
Change the faulty inlet thermistor.
Error Code 33
Change the faulty outlet thermistor.
Error Code 61 or 69
Change the broken blower motor.
Error Code 65
An issue with the water flow solenoid.
Error Code 92
The neutralizer needs to be replaced soon.
Error Code 93
The neutralizer must be replaced.
Error Code P1
Water flow is below the minimum required. Increase the flow.
Rheem Tankless Water Heaters: Common Problems and Solutions
Problem: Not Enough Hot Water or No Hot Water
Ensure that both the water shutoff valve and the hot water tap are fully open. If the temperature setting on the remote is too low, increase it as needed. In the case of a water heater equipped with a mixing valve that is not functioning properly, it may be necessary to replace the valve. Check for any clogs in the water inlet filter or fixture aerator, and if found, clear the blockage. If there is scale build-up in the heat exchanger (indicated by an error code), follow the descaling procedure to remove the scale.
Problem: Water Is Not Hot Enough
Check the thermostat setting on the remote control; it may be set too low. Additionally, verify the gas pressure to ensure it is not too low, and ensure that the gas valve is fully open.
Water Too Hot
The water temperature setting on the remote control is set too high. Check if the water flow is too low or if the shutoff valve is not fully open.
Summary
While the provided list of Rheem tankless error codes can be helpful in effectively troubleshooting the issue, there may be instances where you are unable to resolve the problem, cannot find the exact error code mentioned, or encounter difficulties in fixing the unit. In such cases, it is highly recommended to seek professional assistance to ensure a proper resolution.
When contacting the manufacturer for support, ensure that you have the following information readily available:
- Model and serial number of the water heater.
- Contractor or business name responsible for the installation and service.
- Installation date of the unit.
- Details regarding any previously performed services, including dates.
- Provide comprehensive information about the problem you are experiencing.
Related Articles
-
How to Remove Sediments from a Water Heater and Boost Performance
Are you tired of lukewarm showers and reduced water flow from your trusty water heater? Sediments could be the sneaky culprits behind your plumbing woes. But fear not! In this…
-
RV Water Heater Repair: Revive Your Water Heating System With Expert Troubleshooting Tips
Our comprehensive guide focuses on RV water heater repair, troubleshooting, and fixing common issues. Whether you’re a seasoned RV enthusiast or a novice traveler, we understand that dealing with problems…
-
Why Your RV Water Heater Isn’t Lighting and How to Fix It!
Imagine you’re on a picturesque camping trip, ready to enjoy a warm shower or a hot cup of tea in your cozy RV, only to find that your RV water…